Back to search

Turkey Tail, Yun Zhi · 2025 · Research Article

Medium relevance

Biosensor Based on the Immobilization of Laccase on β-Cyclodextrin Membrane for the Evaluation of Antioxidant Capacity in Real Samples.

Trametes versicolor

OncologyImmune support
SpeciesTurkey Tail, Yun Zhi
JournalChemistryOpen
Year2025

Key points

  • The optimization of a new amperometric biosensor for evaluating antioxidant capacity in real samples is reported
  • The biosensor is based on the immobilization of Laccase from Trametes versicolor on an electropolymerized β-cyclodextrin polymeric membrane on a glassy carbon electrode
  • Variables such as pH, temperature, and enzyme concentration were optimized using a factorial design with two levels for each factor
  • The best biosensor is synthesized at pH 3.0 with 6 mg/mL of enzyme and 30 °C. The biosensor presented a response time of ≤30 seconds and good stability in its amperometric response
  • The biosensor showed excellent stability and good performance regarding response time, stability, and easy fabrication
  • The proposed biosensor is a good option for evaluating antioxidant capacity in real samples without sample pretreatment

Metadata-grounded summary

Citation abstract

The optimization of a new amperometric biosensor for evaluating antioxidant capacity in real samples is reported. The biosensor is based on the immobilization of Laccase from Trametes versicolor on an electropolymerized β-cyclodextrin polymeric membrane on a glassy carbon electrode. The process of electropolymerization, which was successful even in the presence of the enzyme, was a key step in biosensor synthesis. Variables such as pH, temperature, and enzyme concentration were optimized using a factorial design with two levels for each factor. Different electrodes were constructed and tested using caffeic acid as a standard. The best biosensor is synthesized at pH 3.0 with 6 mg/mL of enzyme and 30 °C. The biosensor presented a response time of ≤30 seconds and good stability in its amperometric response. The biosensor was used to evaluate the antioxidant capacity of real samples. Infusions of green, black, red, and white tea were assessed. The biosensor showed excellent stability and good performance regarding response time, stability, and easy fabrication. The proposed biosensor is a good option for evaluating antioxidant capacity in real samples without sample pretreatment. It combines a simple fabrication methodology and a minimal extraction process for rapid and reliable phenolic content determination in real samples.

Citation

Juárez-Gómez J, Alejandro Báez-Melga O, Sarahia Guzmán-Hernández D (2025). Biosensor Based on the Immobilization of Laccase on β-Cyclodextrin Membrane for the Evaluation of Antioxidant Capacity in Real Samples. ChemistryOpen https://doi.org/10.1002/open.202400228 PMID: 39434496

Open citation