Niu-Chang-Chih · 2014 · Research Support, Non U.S. Gov'T
Medium relevanceSeparation of 25R/S-ergostane triterpenoids in the medicinal mushroom Antrodia camphorata using analytical supercritical-fluid chromatography.
Antrodia camphorata
Key points
- Ergostanes are major bioactive constituents of the medicinal mushroom Antrodia camphorata
- In this study, we used analytical supercritical-fluid chromatography (SFC) to separate seven pairs of 25R/S-ergostanes from A. camphorata
- We found that Princeton 2-ethylpyridine column (2-EP, 4.6×250mm, 3μm, achiral) could effectively separate different pairs, although the resolutions for 25-R/S forms of each epimeric pair were not as good as OJ-H column
- Meanwhile, all the (25S)-forms showed stronger retentions than the corresponding (25R)-epimers on the 2-EP column
- These results demonstrated different selectivity of chiral- and achiral-SFC in separating 25R/S-ergostane epimers
- Aside from high separation efficiency, SFC also showed advantage over HPLC in short analysis time and low consumption of organic solvents
From the paper
Abstract
Ergostanes are major bioactive constituents of the medicinal mushroom Antrodia camphorata. These tetracyclic triterpenoids usually occur as 25R/S epimeric pairs, which renders their chromatographic separation difficult. In this study, we used analytical supercritical-fluid chromatography (SFC) to separate seven pairs of 25R/S-ergostanes from A. camphorata. The (R)- and (S)-forms for each of the seven pairs could be well resolved (Rs>1.3) on a Chiralcel OJ-H column (4.6×250mm, 5μm, chiral), eluted by 10% MeOH in CO2 at 2mL/min with a back pressure of 120bar and a column temperature of 40°C. Particularly, this chiral-SFC method could rapidly and efficiently separate low-polarity epimers like antcin A and antcin B, which were very difficult for RP-HPLC. A 3-min preparative-scale method was established to purify (25S)- and (25R)-antcin A for the first time. However, OJ-H column suffered from peak overlapping of different pairs of ergostanes. We found that Princeton 2-ethylpyridine column (2-EP, 4.6×250mm, 3μm, achiral) could effectively separate different pairs, although the resolutions for 25-R/S forms of each epimeric pair were not as good as OJ-H column. Meanwhile, all the (25S)-forms showed stronger retentions than the corresponding (25R)-epimers on the 2-EP column. These results demonstrated different selectivity of chiral- and achiral-SFC in separating 25R/S-ergostane epimers. Aside from high separation efficiency, SFC also showed advantage over HPLC in short analysis time and low consumption of organic solvents. Finally, both OJ-H and 2-EP columns were used on analytical SFC to separate 25R/S-ergostanes in an extract of A. camphorata.
Citation
Qiao X, An R, Huang Y, Ji S, Li L, Tzeng YM, et al. (2014). Separation of 25R/S-ergostane triterpenoids in the medicinal mushroom Antrodia camphorata using analytical supercritical-fluid chromatography. Journal of chromatography. A https://doi.org/10.1016/j.chroma.2014.06.074 PMID: 25017395
Open citation