Cordyceps, Scarlet Club · 2024 · Journal Article
Medium relevanceA novel and sensitive dual signaling ratiometric electrochemical aptasensor based on nanoporous gold for determination of Ochratoxin A.
Cordyceps militaris
Key points
- Ochratoxin A (OTA) is a toxic pollutant in foods, and its actual detection is crucial
- A novel and sensitive dual signaling ratiometric electrochemical aptasensor based on nanoporous gold (NPG) was proposed to determine OTA. NPG, with high specific surface area and conductivity, improved the sensitivity by immobilizing more aptamers
- Meanwhile, the dual signaling ratiometric strategy improved the detection reproducibility through self-referencing and built-in correction
- NPG and ratiometric strategy multi-amplified the dual signal changes
- The sensitivity of OTA was evaluated by the ratio of methylene to ferrocene current values
- Under the optimal conditions, the NPG-based aptasensor demonstrated excellent sensitivity with a wide linear range of 1 pg/mL to 2 ng/mL and the limit of detection (LOD) of 0.4 pg/mL for OTA. This developed aptasensor also effectively detected OTA in spiked Cordyceps sinensis and grape juice samples, with recovery values falling in the 98.49-108.0% range
Metadata-grounded summary
Citation abstract
Ochratoxin A (OTA) is a toxic pollutant in foods, and its actual detection is crucial. A novel and sensitive dual signaling ratiometric electrochemical aptasensor based on nanoporous gold (NPG) was proposed to determine OTA. NPG, with high specific surface area and conductivity, improved the sensitivity by immobilizing more aptamers. Meanwhile, the dual signaling ratiometric strategy improved the detection reproducibility through self-referencing and built-in correction. NPG and ratiometric strategy multi-amplified the dual signal changes. The sensitivity of OTA was evaluated by the ratio of methylene to ferrocene current values. Under the optimal conditions, the NPG-based aptasensor demonstrated excellent sensitivity with a wide linear range of 1 pg/mL to 2 ng/mL and the limit of detection (LOD) of 0.4 pg/mL for OTA. This developed aptasensor also effectively detected OTA in spiked Cordyceps sinensis and grape juice samples, with recovery values falling in the 98.49-108.0% range.
Citation
Wang Y, Yu F, Liu Q, Wang C, Zhu G, Bai L, et al. (2024). A novel and sensitive dual signaling ratiometric electrochemical aptasensor based on nanoporous gold for determination of Ochratoxin A. Food chemistry https://doi.org/10.1016/j.foodchem.2023.137192 PMID: 37633144
Open citation