Reishi, Lingzhi · 2021 · Journal Article
High relevanceIn situ effervescence reaction-assisted mechanochemical extraction of ganoderic acids from Ganoderma lucidum
Ganoderma lucidum
Key points
- The aim of this work was to develop a simple, green and low-consumption method for the extraction of ganoderic acids
- An in situ effervescence reaction-assisted mechanochemical extraction method was proposed, and the effects of independent variations in terms of sodium bicarbonate concentration, milling time, and liquid/solid ratio (mL/g) were investigated by means of a response surface methodology (RSM) Box-Behnken design (BBD)
- The highest yields of ganoderic acids were achieved by grinding a Ganoderma lucidum sample with sodium bicarbonate (372.60 mg/g) and citric acid for 0.87 min with a water to material ratio of 10.58 mL. The linear calibration ranges were from 0.01–5 μg/mL for the six analytes and had good linearity with a correlation coefficient of determination higher than 0.9991
- In addition, the obtained LODs of the six target analytes were 1.46 − 2.97 ng/mL, and the LOQs calculated as ten times the signal-to-noise ratio were 4.88 − 9.90 ng/mL. The proposed method was successfully applied to the Ganoderma lucidum samples
From the paper
Abstract
The aim of this work was to develop a simple, green and low-consumption method for the extraction of ganoderic acids. An in situ effervescence reaction-assisted mechanochemical extraction method was proposed, and the effects of independent variations in terms of sodium bicarbonate concentration, milling time, and liquid/solid ratio (mL/g) were investigated by means of a response surface methodology (RSM) Box-Behnken design (BBD). The highest yields of ganoderic acids were achieved by grinding a Ganoderma lucidum sample with sodium bicarbonate (372.60 mg/g) and citric acid for 0.87 min with a water to material ratio of 10.58 mL. The linear calibration ranges were from 0.01–5 μg/mL for the six analytes and had good linearity with a correlation coefficient of determination higher than 0.9991. In addition, the obtained LODs of the six target analytes were 1.46 − 2.97 ng/mL, and the LOQs calculated as ten times the signal-to-noise ratio were 4.88 − 9.90 ng/mL. The proposed method was successfully applied to the Ganoderma lucidum samples.
Citation
Zhen XT, Chen Y, Yu YL, Shi MZ, Yan TC, Yue ZX, et al. (2021). In situ effervescence reaction-assisted mechanochemical extraction of ganoderic acids from Ganoderma lucidum. Industrial crops and products https://doi.org/10.1016/j.indcrop.2021.113577
Open citation