Cordyceps, Caterpillar Fungus · 2017 · Journal Article
High relevanceBroad-spectrum immunoaffinity cleanup for the determination of aflatoxins B1, B2, G1, G2, M1, M2 in Ophiocordyceps sinensis and its pharmaceutical preparations by ultra performance liquid chromatography tandem mass spectrometry.
Ophiocordyceps sinensis
Key points
- An ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the simultaneous determination of aflatoxins B 1, B 2, G 1, G 2, M 1 and M 2 (AFB 1, AFB 2, AFG 1, AFG 2, AFM 1 and AFM 2 ) in Ophiocordyceps sinensis and its pharmaceutical preparations
- Under the optimized conditions, the home-made immunoaffinity column capacity were about 315, 319, 292, 102, 444 and 369ng/mL gel for AFB 1, AFB 2, AFG 1, AFG 2, AFM 1 and AFM 2, respectively
- Recoveries for all tested aflatoxins ranged from 79.28% to 103.42% with relative standard deviation less than 8%
- The limits of quantitation were in the range of 0.008-0.045μg/kg
- Among 31 real samples analyzed, one sample was contaminated with AFB 1, AFB 2 and AFM 1 at levels of 0.483, 0.068 and 0.104μg/kg, respectively
- The established method is simple, accurate, and can be effectively used to determine the aflatoxins in Ophiocordyceps sinensis and its pharmaceutical preparations
Metadata-grounded summary
Citation abstract
An ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the simultaneous determination of aflatoxins B 1, B 2, G 1, G 2, M 1 and M 2 (AFB 1, AFB 2, AFG 1, AFG 2, AFM 1 and AFM 2 ) in Ophiocordyceps sinensis and its pharmaceutical preparations. A rapid and reliable immunoaffinity column containing a broad-spectrum monoclonal antibody for six aflatoxins was used for sample cleanup. Under the optimized conditions, the home-made immunoaffinity column capacity were about 315, 319, 292, 102, 444 and 369ng/mL gel for AFB 1, AFB 2, AFG 1, AFG 2, AFM 1 and AFM 2, respectively. Recoveries for all tested aflatoxins ranged from 79.28% to 103.42% with relative standard deviation less than 8%. The limits of quantitation were in the range of 0.008-0.045μg/kg. Among 31 real samples analyzed, one sample was contaminated with AFB 1, AFB 2 and AFM 1 at levels of 0.483, 0.068 and 0.104μg/kg, respectively. The established method is simple, accurate, and can be effectively used to determine the aflatoxins in Ophiocordyceps sinensis and its pharmaceutical preparations.
Citation
Sun S, Xie J, Peng T, Shao B, Zhu K, Sun Y, et al. (2017). Broad-spectrum immunoaffinity cleanup for the determination of aflatoxins B1, B2, G1, G2, M1, M2 in Ophiocordyceps sinensis and its pharmaceutical preparations by ultra performance liquid chromatography tandem mass spectrometry. Journal of chromatography. B, Analytical technologies in the biomedical and life sciences https://doi.org/10.1016/j.jchromb.2017.10.013 PMID: 29157467
Open citation